Fire risk assessment for blocks of flats

The common parts, the flat entrance doors, and what the four types of assessment mean.

  • Written report to keep on file
  • Clear action plan, highest risk first
  • Price agreed before booking
Get a price

We reply with a written price.

We use these details to reply to you. See our privacy notice.

The front door of each flat opens onto the stair that everyone else uses to get out. That is why the flat entrance doors matter so much in a block, and why the Fire Safety Act 2021 made it plain that the Fire Safety Order covers them, along with the structure and the external walls, in any building with two or more sets of domestic premises.

The person responsible is usually the freeholder, the residents' management company or the managing agent acting for them. Inside each flat is the leaseholder's or tenant's own business. The stairs, landings, bin store, meter cupboards and roof access are yours.

A ceiling detector and a vent along a narrow white corridor
A ceiling detector and a vent along a narrow white corridor

Type 1, 2, 3 or 4

These four types come from the guide on fire safety in purpose-built blocks of flats, which is published on gov.uk.

Type 1 is common parts only and non-destructive. Nothing is opened up. It still looks at a sample of flat entrance doors from the landing side, and where it can it lifts a few ceiling tiles and opens a few service risers. The guide says a Type 1 will normally be enough for most purpose-built blocks unless there is reason to expect serious problems with compartmentation or fire stopping.

Type 2 is common parts with some destructive inspection, so a contractor opens up and makes good. Type 3 adds a non-destructive look inside a sample of flats, at smoke alarms, escape routes and internal doors. Type 4 does the same with opening up as well. The guide says Type 4 is only appropriate in limited cases, and that destructive work should be preceded by a look at the asbestos register.

A Type 3 is rarely possible in long leasehold flats, because the freeholder usually has no right to go in.

Blocks over 11 metres and over 18 metres

In England, the Fire Safety (England) Regulations 2022 add duties by height. Any building with two or more sets of domestic premises needs fire safety instructions and fire door information given to residents. Above 11 metres there are quarterly checks of communal fire doors and best-endeavours checks of flat entrance doors every 12 months. At 18 metres or seven storeys you add wayfinding signs, a secure information box and building plans for the fire service.

Our fire risk assessors note which of these apply to your block and whether there is evidence they are being done.

Price for a block

Blocks are priced from the floor area, the number of storeys and the type of assessment. Send us the postcode, the number of flats and floors, and the last assessment if there is one.

Need a fire risk assessment in London?

Tell us the postcode, what the building is used for and roughly how big it is. We will come back with a price.

Call 020 3031 1131Get a quote